enters the vial To fully seat the adapter to the top of the vial push downward while rotating adapter a full 720 degrees Prepare vial 1 6 Swab the top of the needle free valve with 70 IPA and allow it to dry 7 Connect the syringe to the needle free valve on a hard and flat surface 8 Inject the desired amount of diluents into the vial
Vial Adapter with Clave allows vial access 13 20 mm with luer tips of syringes Product Numbers List Number shop icumed Number EDI Number Nominal Length 2 5 08 cm Tubing I D 0 090 Priming Capacity Approximate
Remove the lid film of the vial adapter packaging but do NOT remove the vial adapter from its packaging Holding the vial adapter packaging position the vial adapter on top of the vial and push it fully down so that it snaps in place confirmed by an audible click Lift the packaging off the vial adapter
It is designed to puncture the vial septum aspirate medication and simultaneously allow air into the vial to reduce back pressure it has an integral filter intended to prevent the ingress of airborne microbial contaminants Typically the proximal end is a Luer connector The
Helapet 20mm MLL Vial Adapter provides a safe secure and needle free connection between a syringe and any standard 20mm diameter vial Using a refined plastic spike for easy insertion the shrouded adapter design protects the user from the risk of accidental injury
JIVI Antihemophilic Factor Recombinant B domain deleted PEGylated with Vial Adapter with a 15 micrometer filter is a needleless system that prevents needlestick injuries during reconstitution see WARNINGS AND PRECAUTIONS General Infuse JIVI intravenously over a period of 1 to 15 minutes depending on the total volume Adapt
OnGuard Vial Adaptor Benefits of OnGuard CSTD Majority of hazardous drug compounding can be done with just 3 SKU Designed to reduce waste help make implementations easier and reduce confusion Just compound and go No need to pre prime or pre activate the vial adaptor Click to lock No push and twist Linear connection designed to
Company News Filtertek Brings New Vial Adapter to Market New product designed for various vent and liquid filter options HEBRON IL January 2006 Filtertek a leading developer of new medical products for healthcare OEM s now offers a new vial adapter and filtration component system to facilitate medication access reconstitution and transfer
One variant of the vial adapter is integrated with a filter to address various types of particles In the present study the performance of the filter integrated vial adapter is evaluated with respect to glass delamination particles Silica particles of 0 5–10 μm are used to emulate glass delamination particles
West Pharmaceutical Services Inc 13MM VIAL ADAPTER 1500CS Manufacturer West Pharmaceutical Services Inc This product was recently added by
Vented safe handling vial adapter June 2010 Mosler et al Syringe devices and methods for mixing and administering medication June 2010 Tennican et al D616984 Vial adapter having side windows June 2010 Gilboa Method and apparatus for an improved luer fitting connection May 2010 Burton et al D616090
Closed Vial Adaptor Halo s Closed Vial Adaptors are intended for closed preparation of drugs The system is compatible with standard vials with 13mm 20mm and 28mm OD necks which correspond to CVA130 CVA200 and CVA280 respectively
For closed reconstitution and withdrawal of medications with most 20 mm and 13 mm vials with vial converter ring provided Majority of hazardous drug compounding can be done with just 3 SKU Designed to reduce waste help make implementations easier and reduce confusion Just compound and go No need to pre prime or pre activate the vial adaptor
4 Insert the vial in counting adapter the disc facing the detection opening and count WM 10 15 Fig 1 A glass fiber filter disc adhered to the inner wall of a 20 ml vial Wet method WM 1 According to your preference wipe with a dry or moistened disc 2 Insert the disc in the vial Minivial is recommended 3
Call Us Medical professionals medical facility employees 855 571 2100 Need help with SupplyManager 800 422 0280 Accounts Receivable 800 453 5180
The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization In another aspect a third filter medium is used in the vent of the adapter to allow gas to pass in either direction through it but prevents bacteria and particulate matter in the atmosphere from reaching the second filter device
syringe and vial adapter With the other hand hold the IXINITY vial tightly on a clean flat surface In a continuous motion place the vial adapter over the IXINITY vial firmly push the filter spike of the vial adapter through the center of IXINITY vial s rubber circle until the clear plastic cap snaps onto the IXINITY vial See Figure E
West 13 mm Swabable Vial Adapter Vial adapters are a cost effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes Vial adapter spike technology provides a reproducible engineered depth
A vented vial adapter has a filter attached to a vent arm that includes at least two filter media for suppressing aerosolized medicaments from leaving the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization
Helapet Vented Vial Adapters are a safe and easy to use solution for reconstitution of cytotoxics antibiotics and other hazardous chemicals A single use needle free device Helapet Vented Vial Adapters can be securely fastened to any standard 13mm or 20mm diameter vial The novel skirt design prevents the adapter from being detached once
– 1 vial adapter with an integrated particle filter with a pore size of 25 micrometer Vial Type I glass vial closed with a chlorobutyl rubber stopper covered with an aluminium cap The closed vial is equipped with a polypropylene tamper evident snap off cap
Jivi is available with the Vial Adapter needleless reconstitution system which contains 1 Vial Adapter with built in 15 micrometer filter 2 5 mL diluent in a 5 mL syringe 25 gauge butterfly needle
vial adapter50674 ch 7313mm vented vial spike with tritan dianaonco ¿universal spike closed vial clave ch 80 universal locking vented spike vial clave ch 74 transfer setap2 0086sw drill for chemotherapy with air filter drive cairel505 kit integra2990
Use of the Vial Adapter gave better consistency The standard deviation for a 2 mL withdrawal was substantially lower with the Vial Adapter for all groups see the table From this it can be judged that delivery volume to the patient will likewise be more consistentand with better volume of delivery it follows that the amount of overfill
4 Open the Mix2Vial filter transfer set by peeling off the lid Do not remove the transfer set from the blister package 5 Place the Sterile Water for Injection vial on an even clean surface and hold the vial tight Take the transfer set together with the blister package and push the spike of the blue adapter end straight down through
1 2 3 This device partners with the Texium closed male Luer to provide closed system access to drug vials SmartSite needle free valve includes Needle free access to multiple use vials 0 2 micron hydrophobic air venting filter provides Neutralization of vial pressure minimizing aerosols and surface contamination Eases drug extraction
Universal Vial Adapter 1 Vacuum Bottle 1 Vial Access Adapter 1 Vial Access Cap Spike 1 Y Site Connector 1 Zero Reflux IV Connector 1 Embolization Coil 9 Luer Lock Cap 7 Pressure Monitoring Line 7 Tamper Evident Luer Lock Cap 7 Channel Two Diluent Set 6 Sealed Lead Acid Battery Pack 6 Catheter Repair Kit 5 Inflation
Qosina offers an extensive line of luer activated valves in a variety of configurations that are in stock and ready for immediate delivery Ideal for use in applications that require a needle free fluid transfer from a vial Qosina part #80220 is a 13 mm vial adapter that is equipped with a needleless injection site
ViaLok Vented Vial Access Device The ViaLok Vented Vial Access Device is designed with a 0 2 micron filter to allow for venting during fluid withdrawal 20 mm standard closure Universal Easy attachment and superior vial security Integrated grip reduces user
11 Withdraw solution into the syringe by holding the vial on end above the vial adapter and syringe I then draw the plunger rod out slowly and smoothly Ensure that the entire content of the vial is drawn into the syringe 12 With the plunger rod in place remove the syringe from the vial adapter the latter should remain attached to the vial
A vented vial adapter has a filter attached to a vent arm that includes a t least two filter media for suppressing aerosolized medicaments from leavin g the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial
Vial adapters are a cost effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes Vial adapter spike technology provides a reproducible engineered depth for drug and diluent aspiration which greatly reduces the end user variability associated with traditional needle aspirations and helps
One 13 mm vial adapter with 5 micron filter 5 mg per vial Purple NDC One 5 mg SEVENFACT single dose vial NDC One pre filled syringe containing 5 2 mL of Sterile Water for Injection NDC One 20 mm vial adapter with 5 micron filter
CH 62 ChemoClave Vial Spike 13 mm 50 ChemoClave Vented Vial Spikes A 0 22 micron hydrophobic filter automatically equalizes vial pressure Allows access to vials with 13 mm 20 mm and 28 mm closures Item Description Case Qty Product Image CH 70 ChemoClave Universal Vented Vial Spike 20 mm and 28 mm 50 CH 70 5 ChemoClave Universal Vented
Single Vial Adapter for attaching one 10R reagent vial to a CliniMACS Prodigy Tubing Set Sterile and non pyrogenic fluid path One package unit contains five pieces of sealed Single Vial Adapters for single use Great Britain
With the other hand hold the IXINITY vial tightly on a clean flat surface In a continuous motion place the vial adapter over the IXINITY vial firmly push the filter spike of the vial adapter through the center of IXINITY vial s rubber circle until the clear plastic cap snaps onto the IXINITY vial See Figure E Push the plunger down to